1 #
2 # Generic thermal sysfs drivers configuration
3 #
4
5 menuconfig THERMAL
6         tristate "Generic Thermal sysfs driver"
7         help
8           Generic Thermal Sysfs driver offers a generic mechanism for
9           thermal management. Usually it's made up of one or more thermal
10           zone and cooling device.
11           Each thermal zone contains its own temperature, trip points,
12           cooling devices.
13           All platforms with ACPI thermal support can use this driver.
14           If you want this support, you should say Y or M here.
15
16 if THERMAL
17
18 config THERMAL_HWMON
19         bool
20         depends on HWMON=y || HWMON=THERMAL
21         default y
22
23 choice
24         prompt "Default Thermal governor"
25         default THERMAL_DEFAULT_GOV_STEP_WISE
26         help
27           This option sets which thermal governor shall be loaded at
28           startup. If in doubt, select 'step_wise'.
29
30 config THERMAL_DEFAULT_GOV_STEP_WISE
31         bool "step_wise"
32         select STEP_WISE
33         help
34           Use the step_wise governor as default. This throttles the
35           devices one step at a time.
36
37 config THERMAL_DEFAULT_GOV_FAIR_SHARE
38         bool "fair_share"
39         select FAIR_SHARE
40         help
41           Use the fair_share governor as default. This throttles the
42           devices based on their 'contribution' to a zone. The
43           contribution should be provided through platform data.
44
45 config THERMAL_DEFAULT_GOV_USER_SPACE
46         bool "user_space"
47         select USER_SPACE
48         help
49           Select this if you want to let the user space manage the
50           lpatform thermals.
51
52 endchoice
53
54 config FAIR_SHARE
55         bool "Fair-share thermal governor"
56         help
57           Enable this to manage platform thermals using fair-share governor.
58
59 config STEP_WISE
60         bool "Step_wise thermal governor"
61         help
62           Enable this to manage platform thermals using a simple linear
63
64 config USER_SPACE
65         bool "User_space thermal governor"
66         help
67           Enable this to let the user space manage the platform thermals.
68
69 config CPU_THERMAL
70         tristate "generic cpu cooling support"
71         depends on CPU_FREQ
72         select CPU_FREQ_TABLE
73         help
74           This implements the generic cpu cooling mechanism through frequency
75           reduction, cpu hotplug and any other ways of reducing temperature. An
76           ACPI version of this already exists(drivers/acpi/processor_thermal.c).
77           This will be useful for platforms using the generic thermal interface
78           and not the ACPI interface.
79           If you want this support, you should say Y here.
80
81 config SPEAR_THERMAL
82         bool "SPEAr thermal sensor driver"
83         depends on PLAT_SPEAR
84         depends on OF
85         help
86           Enable this to plug the SPEAr thermal sensor driver into the Linux
87           thermal framework
88
89 config RCAR_THERMAL
90         tristate "Renesas R-Car thermal driver"
91         depends on ARCH_SHMOBILE
92         help
93           Enable this to plug the R-Car thermal sensor driver into the Linux
94           thermal framework
95
96 config EXYNOS_THERMAL
97         tristate "Temperature sensor on Samsung EXYNOS"
98         depends on (ARCH_EXYNOS4 || ARCH_EXYNOS5)
99         depends on CPU_THERMAL
100         help
101           If you say yes here you get support for TMU (Thermal Management
102           Unit) on SAMSUNG EXYNOS series of SoC.
103
104 config DB8500_THERMAL
105         bool "DB8500 thermal management"
106         depends on ARCH_U8500
107         default y
108         help
109           Adds DB8500 thermal management implementation according to the thermal
110           management framework. A thermal zone with several trip points will be
111           created. Cooling devices can be bound to the trip points to cool this
112           thermal zone if trip points reached.
113
114 config DB8500_CPUFREQ_COOLING
115         tristate "DB8500 cpufreq cooling"
116         depends on ARCH_U8500
117         depends on CPU_THERMAL
118         default y
119         help
120           Adds DB8500 cpufreq cooling devices, and these cooling devices can be
121           bound to thermal zone trip points. When a trip point reached, the
122           bound cpufreq cooling device turns active to set CPU frequency low to
123           cool down the CPU.
124