]> rtime.felk.cvut.cz Git - vajnamar/linux-xlnx.git/commit
i2c: cadence: Fix power management order of operations
authorTopi Kuutela <topi.kuutela@gmail.com>
Wed, 11 May 2016 09:55:51 +0000 (12:55 +0300)
committerMichal Simek <michal.simek@xilinx.com>
Mon, 16 May 2016 06:34:41 +0000 (08:34 +0200)
commit06416af3a95082d5d459c8a532acaadc91a20138
treec67643dba640243314df1f79c0c2558a4fc42023
parenteb7ad67d63db5cae6e94fceb35903c7ccce1e4b0
i2c: cadence: Fix power management order of operations

E.g. pm_runtime_set_active must be called while the power
management system is disabled. Fixes extra hanging clk_enable.

Signed-off-by: Topi Kuutela <topi.kuutela@murata.com>
Acked-by: Sören Brinkmann <soren.brinkmann@xilinx.com>
Signed-off-by: Michal Simek <michal.simek@xilinx.com>
drivers/i2c/busses/i2c-cadence.c